Skip to content

Software and

MANUALS

Bionova® Traceability Software for Automatic Readout and Traceability of Rapid, Super Rapid, and Ultra Rapid Biological Indicators and Hygiene Monitoring System was designed to be used as the main tool for traceability and storage of results from biological indicators’ fluorescence readout.

This system allows to link all the information of the BI with the sterilizer and its manufacturer, the operator, the cycle characteristics and all the relevant data of the sterilization activities. It allows data to be stored, documented and historically processed in a more useful and flexible database.

In addition, the last version has incorporated the traceability of the Hygiene Monitoring System, allowing to monitor the protein pen incubation status and to save all the quantitative measurements. This tool is operationally available since version 2.2 of the Bionova® software.

Last version

AVAILABLE

4.5

 

  • Stability improvements.
  • Temporarily disabled time synchronization functionality through the toolbar.
  • Updated company logo

MINIMUM REQUIREMENTS

Operating System Windows 7 or higher.

Net Framework 4.0.

If your PC or notebook has Windows XP, you must download version 2.4 of Bionova® (later versions are not compatible).

BioUpdate

(Firmware update)

This program will allow you to update the firmware of your device, thus keeping it at its best operating level.

Versions

PREVIOUS

4.4

 

  • General corrections were made.
  • The name of “Bionova® Exchange Express” was changed to “Bionova® Exchange+”.
  • The option of printing results in PDF is removed.
  • Japanese is added to the list of compatible languages.

4.3

 

  • Communication security is improved. You must update the incubator firmware in order to use this version.
  • A new tool was incorporated, capable of generating a virtual ticket similar to the printed one, thus allowing the access to the last 50 incubations.
  • A new mode of Bionova ® Exchange License was added, in order to facilitate the exchange of data between systems.
  • All Biological and Hygiene Indicators’ incubations now have an identifying Ticket Number, also available on the incubator’s printed ticket.
  • Several functioning improvements.
  • Minor corrections in several languages.
4.2
  • The mandatory fields to be completed are indicated more clearly.
  • Text and labels corrections.
  • Improvement in IC1020FRLCD detection.
  • Minor corrections and improvements of functionality.
  • On the Chemical Indicator Results tabs, the “User Evaluation” column was added.

4.1

  • For cleaning indicators that were rejected, the detected ink area is marked.
  • Various improvements.

4.0

  • The compatibility of the “Automatic System for Quality Control and Traceability of Cleaning, Disinfection and Sterilization Processes Trazanto” is incorporated.
  • Setting of the number of mandatory fields to be filled in using the “Mandatory fields level” option.
  • Various usability and connectivity enhancements.

3.5

  • A new module called Bionova® Exchange is incorporated, which serves as an interface between compatible incubators and third party software, generating available files for the user to implement information exchange between the systems.
  • Traditional Chinese Language is added.
  • Korean Language is added.

3.4

  • General improvements.

3.3

  • Added functionality for fast PRO data loading via barcode Reading.
  • Chinese language was added.
  • Minor corrections

3.2

  • PRO1VTN and PRO1VTP products added.
  • Load and calculation improvements for tool HTM01-01
  • General improvements to PRO section.
  • General improvements.

3.1

  • Threshold selection is added for Pro1 Micro hygiene indicator results.
  • Improvements in data loading.
  • Improvements in detection service.

3.0

  • Support for incubator IC10/20FRLCD.
  • Support for multiple connected incubators.
  • Notifications of results in the background.
  • Possibility of user switching with ongoing incubations.
  • Wizard to configure WILINK.
Note 1: To run version 3.0 you need to have administrator rights on the operating system.
 
Note 2: Within the same network, version 3.0 of the Bionova® Software can be run on only one computer. Any other configurations do not ensure the correct collection of data.

2.4

  • The new programs corresponding to the new biological indicators were added: BT96 and BT224.
  • Temperature calibration functionality was added for MiniPro with its respective calibration certificate.

2.3

  • Incorporation of a new tool to establish an Internal Quality Assurance Scheme (IQAS) to monitor the efficiency of the cleaning process over time.
  • The time for the next temperature calibration was changed from 6 months to 12 months, in the certificates issued.
  • Available for IC10/20FR, Bionova® MiniBio and Bionova® MiniPro.
  • Download here the updated leaflet / product description.
  • Download here the updated user manual.

Incubator

COMPATIBILITY MATRIX

IC10/20
Download here
the product description.
IC10/20FR
Download here
the product description.
IC10/20FRLCD
Download here
the product description.
MINIBIO
Download here
the product description.
MINIPRO
Download here
the product description.